Products

  • GDF-3000 DC System Earth Fault Detector

    GDF-3000 DC System Earth Fault Detector

    In DC system, there are many earth faults including indirect earth fault, non-metal earth fault, loop earth fault, positive and negative earthing fault, positive and negative balance earth fault, multi-point earth fault.

     

  • GDCR1000C Non-contact Phase Sequence Tester

    GDCR1000C Non-contact Phase Sequence Tester

    GDCR1000C, GDCR1000D non-contact phase tester is a major breakthrough in traditional phase sequence detection method.

  • GDYM-3M Multi-functional Electric Energy Meter Calibrator

    GDYM-3M Multi-functional Electric Energy Meter Calibrator

    The errors, voltage, current, active and reactive power, phase, frequency, and power factor can be measured simultaneously, also vector figure and wiring results will be displayed.

  • GDPQ-5000 Power Quality Analyzer

    GDPQ-5000 Power Quality Analyzer

    GDPQ-5000 Power Quality Analyzer is a comprehensive test instrument carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, concise man-machine operation.

     

  • GDPQ-300E Power Quality Analyzer

    GDPQ-300E Power Quality Analyzer

    GDPQ-300E Power Quality Analyzer is a portable device of testing and analyzing power system operation quality. It monitors and collects data in long running time, also provides harmonic analysis and power quality analysis.

  • GDCF Series Battery Charge and Discharge Load Bank

    GDCF Series Battery Charge and Discharge Load Bank

    This multi-functional instrument provides comprehensive scientific testing method for battery and UPS power supply maintenance. It has charging, discharging, single-unit detection, online monitoring and activation functions. This all-in-one test set reduce the labor intensity of maintenance personnel and enterprise costs.

     

     

  • GDKH-12 Lead Acid Battery Regenerator

    GDKH-12 Lead Acid Battery Regenerator

    The device is a special device for activating a valve-regulated lead-acid battery with a battery voltage of 2V, 6V, or 12V and a backward capacity due to sulfide crystallization of an electrode plate.

  • GDUP Series AC Power Supply

    GDUP Series AC Power Supply

    The GDUP-6000 (GDUP-3000) is a versatile portable pure sine wave on-site AC test power supply. Also known as on-site AC and DC test power supply, AC and DC emergency power supply, field test power supply, mobile test power supply.

     

  • DC Power Supply GDWY-250V.15A

    DC Power Supply GDWY-250V.15A

    It is widely used in power DC system, industrial control, communication, and battery charging equipment and for scientific research.

  • GDBT-8610B Battery Cell Impedance Tester

    GDBT-8610B Battery Cell Impedance Tester

     

     

    Regular maintenance and test is a “must-have” procedure for standby batteries. GDBT-8610B uses the most advanced AC discharge test method, which can accurately measure voltage and internal resistance of battery, to judge the battery capacity and technical status.

     

     

  • GDCP-510 Oil Freezing Point Tester

    GDCP-510 Oil Freezing Point Tester

    GDCP-510 Low Temperature Freezing Point Tester is compliant with GB/T 510 “Determination of Solidification Point for Petroleum Products” and GB/T 3535 “Petroleum Products―Determination of Pour Point. 

  • GDKS-205  Automatic Flash Point Open Cup Tester

    GDKS-205 Automatic Flash Point Open Cup Tester

    GDKS-205 automatic open cup flash point tester is the device testing open cup flash point for petroleum products. It use module design which one host can control several testing furnace, to test different samples at the same time or separately. 

Send your message to us:

Write your message here and send it to us